Aprašymas

It is designed for automatic switching on and off of the central heating circulation pump or the domestic hot water heater loading pump or the circulation pump, depending on the temperature measured on the sensor.

The controller has the following functions:

-intuitive temperature setting using the knob
-controlling the operation of the central heating circulation pump or operation of the pump loading the domestic hot water heater or operation of the circulation pump
-possibility of switching on continuous operation
-COMFORT SYSTEM function, protecting the pump against limescale
-installation protection function against freezing and overheating
-signal of temperature sensor damage.

PLUS mode: in the PLUS mode, the controller controls the operation of the pump that loads the domestic hot water heater or the operation of the circulation pump. Switching the pump on and off is done in the opposite way – the pump works when the temperature on the sensor is lower than the set value, and stops working when the temperature rises to the set level.

Technical data HYDROS 200
Measured temperature range from – 9 ⁰C to + 99 ⁰C
Temperature setting range from + 10 ⁰C to + 90 ⁰C
Central heating pump hysteresis (on / off difference) 2⁰C
Output load capacity pump: 100 W / 230 V
Rated supply voltage 230 V, 50 Hz
Electric protection 1,25 A
Relative air humidity < 95 %
Protection class IP40
Insulation class II
Controller dimensions 145 x 90 x 45 mm
Ambient temperature from 0 ⁰C to + 40 ⁰C