It is designed to control the temperature of a solid fuel boiler by opening and closing the flap regulating the air supply to the furnace. Additionally, the device controls the operation of the circulation pump.
-Maintaining the set temperature of the boiler by controlling the air intake
-The function of supporting the combustion process, the so-called blowing
-Automatic switching off of the control after extinguishing the boiler
-The flap is lowered in the event of a power failure
-Closing the air inlet when adding fuel to the boiler
-Central heating circulation pump control
-COMFORT SYSTEM function, which protects the pump against limescale
-The function of protecting the installation against freezing and overheating of the boiler
-Signal of temperature sensor damage
-Engine lock / failure signaling
-Adjustable display brightness – increased when changing settings
-Possibility to connect the CONTROL remote control panel with an audible alarm function
| Technical data | UNISTER P4 |
| Measured temperature range | from – 9 ⁰C to + 99 ⁰C |
| Temperature setting range for the boiler | from + 40 ⁰C to + 85 ⁰C |
| Air intake flap lifting hysteresis | from 0 ⁰C to 9 ⁰C |
| Temperature setting range for the central heating pump | from + 35 ⁰C to + 70 ⁰C |
| Central heating pump hysteresis (on / off difference) | 2 ⁰C |
| Blow-through adjustment | work: 0 – 90 sekund break: 1 – 15 minut |
| Rated supply voltage | 230 V, 50 Hz |
| Rated load power | 275 W |
| Permitted power of the central heating pump | 100 W / 230 V |
| Relative air humidity | < 95% |
| Protection class | IP 40 |
| Insulation class | I |
| Controller dimensions | 125 x 115 x 53 mm |
| Ambient temperature | from 0⁰C to + 40⁰C |
| Electric protection | 1,25 A |
| Automatic STOP – when there is no fuel in the boiler | yes |