It is designed to control the temperature of a solid fuel boiler by opening and closing the flap regulating the air supply to the furnace. Additionally, the device controls the operation of the circulation pump.    

-Maintaining the set temperature of the boiler by controlling the air intake
-The function of supporting the combustion process, the so-called blowing
-Automatic switching off of the control after extinguishing the boiler
-The flap is lowered in the event of a power failure
-Closing the air inlet when adding fuel to the boiler
-Central heating circulation pump control
-COMFORT SYSTEM function, which protects the pump against limescale
-The function of protecting the installation against freezing and overheating of the boiler
-Signal of temperature sensor damage
-Engine lock / failure signaling
-Adjustable display brightness – increased when changing settings
-Possibility to connect the CONTROL remote control panel with an audible alarm function


Technical data UNISTER P4
Measured temperature range from – 9 ⁰C to + 99 ⁰C
Temperature setting range for the boiler from + 40 ⁰C to + 85 ⁰C
Air intake flap lifting hysteresis from 0 ⁰C to 9 ⁰C
Temperature setting range for the central heating pump from + 35 ⁰C to + 70 ⁰C
Central heating pump hysteresis (on / off difference) 2 ⁰C
Blow-through adjustment work: 0 – 90 sekund
break: 1 – 15 minut
Rated supply voltage 230 V, 50 Hz
Rated load power 275 W
Permitted power of the central heating pump 100 W / 230 V
Relative air humidity < 95%
Protection class IP 40
Insulation class I
Controller dimensions 125 x 115 x 53 mm
Ambient temperature from 0⁰C to + 40⁰C
Electric protection 1,25 A
Automatic STOP – when there is no fuel in the boiler yes