<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>REGUL.MASTER.500 - HydroLand</title>
	<atom:link href="https://hydroland.lt/prekes-kodas/regul-master-500/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Elektroninė parduotuvė</description>
	<lastBuildDate>Sat, 22 Feb 2025 19:37:20 +0000</lastBuildDate>
	<language>lt-LT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://hydroland.lt/wp-content/uploads/2021/01/cropped-hydroland-logo-1467029119-32x32.png</url>
	<title>REGUL.MASTER.500 - HydroLand</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Katilo temperatūros reguliatorius Master 500, su maitinimu</title>
		<link>https://hydroland.lt/product/katilo-temperaturos-reguliatorius-master-500-su-maitinimu_regul-master-500/</link>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 05 May 2021 09:41:51 +0000</pubDate>
				<guid isPermaLink="false">https://hydroland.lt/product/katilo-temperaturos-reguliatorius-master-500-su-maitinimu_regul-master-500/</guid>

					<description><![CDATA[<p>It is designed to control the operation of a boiler with automatic fuel feeding, central heating pump and domestic hot water pump in central heating systems. Maintaining the set temperature of the boiler by controlling the blowing and operation of the feeder Possibility to operate the boiler with an emergency grate Smooth fan operation and [...]</p>
<p>The post <a href="https://hydroland.lt/product/katilo-temperaturos-reguliatorius-master-500-su-maitinimu_regul-master-500/">Katilo temperatūros reguliatorius Master 500, su maitinimu</a> appeared first on <a href="https://hydroland.lt">HydroLand</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>It is designed to control the operation of a boiler with automatic fuel feeding, central heating pump and domestic hot water pump in central heating systems.</p>
<p>Maintaining the set temperature of the boiler by controlling the blowing and operation of the feeder</p>
<p>Possibility to operate the boiler with an emergency grate</p>
<p>Smooth fan operation and adjustable power</p>
<p>The function of supporting the combustion process, the so-called blowing</p>
<p>Adjustable extinguishing time and automatic switching off of the control in the event of absence of fuel</p>
<p>Central heating circulation pump operation control</p>
<p>Possibility to enable or disable domestic hot water priority</p>
<p>Control of the Domestic Hot Water loading pump depending on the required temperature</p>
<p>Possibility of boiler operation and domestic hot water pump according to one of the several weekly programs</p>
<p>Option to work in SUMMER mode</p>
<p>COMFORT SYSTEM function, which protects the pump against limescale</p>
<p>Protection system &#8211; TERIK thermal fuse as additional, mechanical boiler protection against uncontrolled temperature rise</p>
<p>The function of protecting the installation against freezing and overheating of the boiler</p>
<p>Signaling of temperature sensors damage</p>
<p>Adjustable display brightness &#8211; increased when the settings are changed</p>
<p>Possibility to connect a remote control panel with an audible alarm function</p>
<p>Possibility to connect a room thermostat</p>
<p>Large, clear, alphanumeric LCD display 2 x 16 characters</p>
<table style="height: 405px;" width="653">
<tbody>
<tr>
<td>Technical data</td>
<td>MASTER 500</td>
</tr>
<tr>
<td>Measured temperature range</td>
<td>from &#8211; 9 ⁰C to + 120 ⁰C</td>
</tr>
<tr>
<td>Temperature setting range for the boiler</td>
<td>from + 40 ⁰C to + 85 ⁰C</td>
</tr>
<tr>
<td>Temperature setting range for the Domestic Hot Water heater</td>
<td>from + 40 ⁰C to + 70 ⁰C</td>
</tr>
<tr>
<td>Temperature setting range for the Central Heating heater</td>
<td>from + 30 ⁰C to + 70 ⁰C</td>
</tr>
<tr>
<td>Smooth fan start</td>
<td>yes</td>
</tr>
<tr>
<td>Adjustable maximum fan power</td>
<td>40 % &#8211; 100 %</td>
</tr>
<tr>
<td>Fan hysteresis (on-off difference)</td>
<td>od 1 ⁰C do 9 ⁰C</td>
</tr>
<tr>
<td>Dometic Hot Water pump hysteresis (on-off difference)</td>
<td>od 2 ⁰C do 9 ⁰C</td>
</tr>
<tr>
<td>Blow-through adjustment (blow-by turn off completely)</td>
<td>work: 0 &#8211; 90 sekund<br />
break: 1 &#8211; 60 minut</td>
</tr>
<tr>
<td>Adjustable shutdown time of the boiler</td>
<td>0 &#8211; 45 minutes</td>
</tr>
<tr>
<td>Permissible load of outputs</td>
<td>fan: 100 W, 230 V<br />
feeder: 100 W, 230 V<br />
c.h. pump.: 100 W, 230 V<br />
d.h.w. pump: 100 W, 230 V</td>
</tr>
<tr>
<td>Rated supply voltage</td>
<td>230 V, 50 Hz</td>
</tr>
<tr>
<td>Electric protection</td>
<td>2,5 A</td>
</tr>
<tr>
<td>Relative air humidity</td>
<td>&lt; 95%</td>
</tr>
<tr>
<td>Casing protection class</td>
<td>IP 20</td>
</tr>
<tr>
<td>Ambient temperature</td>
<td>from 0⁰C to + 40⁰C</td>
</tr>
</tbody>