<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>REGUL.EKOSTER.400 - HydroLand</title>
	<atom:link href="https://hydroland.lt/prekes-kodas/regul-ekoster-400/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Elektroninė parduotuvė</description>
	<lastBuildDate>Wed, 15 Mar 2023 10:19:06 +0000</lastBuildDate>
	<language>lt-LT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://hydroland.lt/wp-content/uploads/2021/01/cropped-hydroland-logo-1467029119-32x32.png</url>
	<title>REGUL.EKOSTER.400 - HydroLand</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Kietojo kuro katilo temperatūros reguliatorius EkoSter 400</title>
		<link>https://hydroland.lt/product/kietojo-kuro-katilo-temperaturos-reguliatorius-ekoster-400_regul-ekoster-400/</link>
		
		<dc:creator><![CDATA[Admin]]></dc:creator>
		<pubDate>Wed, 05 May 2021 09:41:51 +0000</pubDate>
				<guid isPermaLink="false">https://hydroland.lt/product/kietojo-kuro-katilo-temperaturos-reguliatorius-ekoster-400_regul-ekoster-400/</guid>

					<description><![CDATA[<p>It is designed to control the boiler blow-in, turn off the circulation pump in heating systems and the domestic hot water heater loading pump (DHW). Maintaining the set temperature of the boiler by controlling the blow-in Modulated and set fan power; smooth start The function of supporting the combustion process, the so-called blowing Adjustable time [...]</p>
<p>The post <a href="https://hydroland.lt/product/kietojo-kuro-katilo-temperaturos-reguliatorius-ekoster-400_regul-ekoster-400/">Kietojo kuro katilo temperatūros reguliatorius EkoSter 400</a> appeared first on <a href="https://hydroland.lt">HydroLand</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>It is designed to control the boiler blow-in, turn off the circulation pump in heating systems and the domestic hot water heater loading pump (DHW).</p>
<p>Maintaining the set temperature of the boiler by controlling the blow-in</p>
<p>Modulated and set fan power; smooth start</p>
<p>The function of supporting the combustion process, the so-called blowing</p>
<p>Adjustable time of burning off and automatic switching off of the control after burning off the boiler</p>
<p>Stopping the fan operation while feeding fuel to the boiler / shutting down the boiler</p>
<p>Central heating circulation pump operation control</p>
<p>Option to enable or disable hot water priority</p>
<p>Control of the Domestic Hot Water loading pump depending on the required temperature</p>
<p>Possibility to work in the SUMMER mode</p>
<p>COMFORT SYSTEM function, which protects the pump against limescale</p>
<p>The function of protecting the installation against freezing and overheating of the boiler</p>
<p>Signaling of temperature sensors damage</p>
<p>Adjustable display brightness &#8211; increased when the settings are changed</p>
<p>Possibility to connect a remote control panel with an audible alarm function</p>
<p>Possibility to connect a room thermostat<br />  <br />Large, clear, alphanumeric LCD display 2 x 16 characters</p>
<p> </p>
<table width="618">
<tbody>
<tr>
<td>Technical data</td>
<td>EKOSter 400</td>
</tr>
<tr>
<td>Measured temperature range</td>
<td>from &#8211; 9 ⁰C to + 120 ⁰C</td>
</tr>
<tr>
<td>Temperature setting range for the boiler</td>
<td>from + 40 ⁰C to + 90 ⁰C</td>
</tr>
<tr>
<td>Temperature setting range for the Domestic Hot Water heater</td>
<td>from + 40 ⁰C to + 70 ⁰C</td>
</tr>
<tr>
<td>Adjustable heating pump activation thereshold</td>
<td>min. 35 ⁰C</td>
</tr>
<tr>
<td>Smooth airflow regulation (modulation)</td>
<td>yes</td>
</tr>
<tr>
<td>Adjustable minimum fan power</td>
<td>30 % &#8211; 70 %</td>
</tr>
<tr>
<td>Adjustable maximum fan power</td>
<td>30 % &#8211; 100 %</td>
</tr>
<tr>
<td>Vent hysteresis (on-off difference)</td>
<td>from 0 ⁰C to 9 ⁰C</td>
</tr>
<tr>
<td>Dometic Hot Water pump hysteresis (on-off difference)</td>
<td>from 2 ⁰C to 9 ⁰C</td>
</tr>
<tr>
<td>Blow-through adjustment (blow-by turn off completely)</td>
<td>work: 0 &#8211; 90 seconds<br />break: 1 &#8211; 60 minutes</td>
</tr>
<tr>
<td>Adjustable shutdown time of the boiler</td>
<td>0 &#8211; 45 minutes</td>
</tr>
<tr>
<td>Permissible load of outputs</td>
<td>blowing: 100 W, 230 V<br />central heating pump: 100 W, 230 V<br />domestic hot water: 100 W, 230 V</td>
</tr>
<tr>
<td>Rated supply voltage</td>
<td>230 V, 50 Hz</td>
</tr>
<tr>
<td>Electric protection</td>
<td>2,5 A</td>
</tr>
<tr>
<td>Relative air humidity </td>
<td>&lt; 95%</td>
</tr>
<tr>
<td>Casing protection degree</td>
<td>IP 20</td>
</tr>
<tr>
<td>Ambient temperature</td>
<td>from 0⁰C to + 40⁰C</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://hydroland.lt/product/kietojo-kuro-katilo-temperaturos-reguliatorius-ekoster-400_regul-ekoster-400/">Kietojo kuro katilo temperatūros reguliatorius EkoSter 400</a> appeared first on <a href="https://hydroland.lt">HydroLand</a>.</p>